Environmental sustainability in non-residential buildings by automating and optimization LENI index

2018

Directive 2002/91 / EC as amended by 2010/31 / EU introduces procedures for energy certification aimed to determine, through the numerical indicators, the overall energy efficiency of the buildings, but notes the thermal and electric consumption. Often, the power consumption is incorrectly underestimated, this consumption would to be considered with great attention. In fact, compared to a committed capacity of less, compared to thermal plants, have times of utilization often far higher, leading to energy requirements to levels similar or even higher than those thermal, being the conversion factor of the electrical energy increasingly high. Leaving aside the procedural scheme energy certific…

Consumption (economics)Computer science020209 energyElectric potential energyLighting Buildings Control systems Manuals Mathematical model Optimization IndexesConversion factor02 engineering and technologyCertificationEnvironmental economicsElectric lightSettore ING-INF/04 - AutomaticaSustainability0202 electrical engineering electronic engineering information engineeringDaylightEfficient energy use2018 Thirteenth International Conference on Ecological Vehicles and Renewable Energies (EVER)
researchProduct

Experimental calibration of flat jacks for in-situ testing of masonry

2018

Flat-jack testing method is one of the most commonly used techniques for the structural assessment of existing masonry structures. Single and double flat jacks are usually adopted to evaluate the acting normal stress, or the compressive behaviour of masonry material. Test procedures are codified by international standards (e.g., A.S.T.M D4729-87; C1196-04; C1197-04, R.I.L.E.M TC 177–MDT D.4; R.I.L.E.M. TC 177–MDT D.5), which provide the preliminary calibration of an experimental coefficient (km) and of the effective area (Aeff), which determination influences significantly the reliability of the test. This article presents the result of an experimental study on the calibration of flat jacks…

In situconversion factorVisual Arts and Performing Artsbusiness.industrycompressive stre0211 other engineering and technologies020101 civil engineering02 engineering and technologyConservationStructural engineeringMasonry0201 civil engineeringCompressive strengthmasonry021105 building & constructionArchitectureCalibrationflat-jack methodbusinessGeologyInternational Journal of Architectural Heritage